Ds-3004 Multi-purpose Obstetric Table,Medical Obstetric Table,Delivery Bed Pukang Medical Instruments Co., Ltd. , http://www.xs-medicalbeds.com
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
Set temperature and skin temperature can be displayed separately;
Main body is made of stainless steel;
Double sides phototherapy radiant box;
Acrylic glass bassinet;
APGAR timer;
Timer to count phototherapy time;
Failure alarm indication;
RS232 connector;
Disposable skin temperature sensor is optional.
Standard Configuration:
Warmer module, temperature controller, bassinet, phototherapy radiant box, and the stand.
Specification:
Power requirement: Â AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor: ±0.2ºC        Â
Temperature uniformity of mattress: ≤2ºC
Dominant wavelength of blue light: 400-550nm
Timing range of blue light: 0~9999hrs 59min
APGAR timer: audible and visible  alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Average value of general bilirubin radiation on the mattress effective range:
≥250uW/cm2(the above phototherapy equipment)
≥600uW/cm2(the nether phototherapy equipment)
Bilirubin uniformity of radiating on the mattress effective range: >0.4
Â
Cuna Radiante Termica Hospital Baby Infant Radiant WarmerÂ
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
Set temperature and skin temperature can be displayed separately;
Main body is made of stainless steel;
Double sides phototherapy radiant box;
Acrylic glass bassinet;
APGAR timer;
Timer to count phototherapy time;
Failure alarm indication;
RS232 connector;
Disposable skin temperature sensor is optional.
Standard Configuration:
Warmer module, temperature controller, bassinet, phototherapy radiant box, and the stand.
Specification:
Power requirement: Â AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor: ±0.2ºC        Â
Temperature uniformity of mattress: ≤2ºC
Dominant wavelength of blue light: 400-550nm
Timing range of blue light: 0~9999hrs 59min
APGAR timer: audible and visible  alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Average value of general bilirubin radiation on the mattress effective range:
≥250uW/cm2(the above phototherapy equipment)
≥600uW/cm2(the nether phototherapy equipment)
Bilirubin uniformity of radiating on the mattress effective range: >0.4
Â
Cuna Radiante Termica Hospital Baby Infant Radiant Warmer
Model NO.: IRW-2000A
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: Double Sides Phototherapy Radiant Box
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: No
X-ray Cassette: No
Tilt Angle of Bed: No
Heater Head: No
LED Observation Light: No
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Model NO.: IRW-2000A
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: Double Sides Phototherapy Radiant Box
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: No
X-ray Cassette: No
Tilt Angle of Bed: No
Heater Head: No
LED Observation Light: No
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Cuna Radiante Termica Hospital Baby Infant Radiant WarmerÂ