Hongxing Evaporative Cooling Unit is an energy-saving unit independently researched and developed by Guangzhou Hengxing Refrigeration Equipment Group. The unit is suitable for central air-conditioning projects and industrial refrigeration projects. The advantages of the year are as follows: 1. The evaporative cooling unit can save the running cost of the middle cooling water circulating pump. If it is a traditional chiller, it needs to be equipped with a cooling water pump. It is assumed that the cooling circulating pump is designed according to 37KW, and the annual running time is calculated according to 270 days (37KW*24 hours). *270 days = 239760KW), saving 240,000 kilowatts of electricity per year; 2. When the high temperature and high pressure Freon enters the circulation inside the evaporative condenser, it is directly cooled by the external spray water and the fan air, which is equivalent to generating only one cooling heat exchange. The ordinary cooling tower form is equivalent to secondary cooling, and the cooling water is cooled by the cooling tower and then enters the shell-and-tube condenser for heat exchange with Freon. Therefore, the condensation temperature of the evaporative cooling unit under the same conditions is 5 degrees lower than that of the water-cooled unit and 15 degrees lower than that of the air-cooled unit. Under the same cooling capacity, the compressor of the evaporative cooling unit consumes 17% less electricity than the water-cooled unit and 37% lower than the air-cooled unit. 3. Since the evaporative condenser utilizes the evaporative cooling heat exchange method efficiently, the heat exchange area, the number of fans, and the power consumption of the fan motor can be effectively reduced. The power of the evaporative condenser fan is approximately 1/3 of the power of an air-cooled condenser fan of the same specification. 4. Considering the whole system comprehensively, under the same cooling capacity, under the same cooling capacity, the compressor of the evaporative cooling unit consumes 20% less electricity than the water-cooled unit and 40% lower than the air-cooled unit. The evaporative condenser integrates the cooling tower, condenser, circulating water tank, circulating water pump and water pipe, which reduces equipment such as cooling towers, circulating water pumps and water pipes, and reduces the handling and installation of individual components in the cooling tower/condenser system. cost of. The evaporative condenser saves valuable space by combining the condenser coil and the cooling tower, and there is no need to require larger pumps and piping to the cooling tower/condenser system. Evaporative condensers require only about 50% of the windward area of ​​an air-cooled condenser of the same specification. The evaporative condenser has a water spray of 1/4 of that of a conventional cooling tower system, so the water consumption of the evaporative cooling system is 1/4 of that of a conventional water cooling system. In the actual use environment of the shell-and-tube condenser, due to the use of the open cooling tower, on the one hand, the dust in the air will fall into the cooling tower. On the one hand, the water quality is very likely to breed algae microorganisms at the temperature of the cooling water, and the inner wall of the copper tube It is easy to scale after a long time, and it is difficult to carry out internal cleaning. If a large amount of acid is used for cleaning, it may cause damage to the copper tube and cause internal leakage, which may cause further compressor burnout, and the use of evaporative condenser avoids this defect. . Insulin Syringes Needle,Disable Syringe,Monoject Syringe,10 Ml Syringe FOSHAN PHARMA CO., LTD. , https://www.foshanmedicine.com First, efficient energy saving
Second, save initial investment
Third, save space
Fourth, save water
Five, easy to use