I. Functional characteristics The IM series automatic ice making machine produced by our company has the shape of rectangular parallelepiped and stainless steel shell. The appearance is beautiful and elegant. It has the characteristics of fast ice making speed, large ice making capacity, transparent icicles and fast deicing speed. From the influent water injection, ice making, water discharge, deicing, ice storage, a series of processes to achieve automatic computer-controlled continuous ice making, if there is a lack of water or ice in the refrigerator, the corresponding instructions on the operation panel of the ice crusher The light will flash, the ice machine will automatically stop, and it has good protection. Since the storage refrigerator adopts a rigid foaming structure, the heat preservation performance is good, so that the ice cubes produced are not easily melted. In addition, the ice machine is reused after each ice is finished, which not only saves water resources, but also improves the ice making efficiency, reduces energy consumption, and greatly reduces the user's ice making costs. Therefore, it has a green and environmentally friendly effect. According to the different methods of water use for ice making, pure water ice and tap water ice can be used respectively.

Second, before use 1. The tilt angle of the box when transporting should not be greater than 45 degrees, prohibiting inversion, so as not to cause failure of the compressor or refrigeration system.


2. If the ice machine is used for the first time or after long-term shutdown, the drain nut 5 should be unscrewed, and the self-prepared container should be placed in the water storage position. The first two ice making processes are the cleaning process of the ice machine piping system. Ice cubes should not be eaten. Wait until the drain is drained twice. Tighten the drain nut 5 and eat the ice cube.
3. The ice machine cannot be used outdoors in the open air. Do not spray directly. Do not place it in a place that is wet or easily exposed to water. It should be placed on a well-ventilated plane away from the heat source, surrounded by non-corrosive gases, and at least 150mm space is left around to ensure the free flow of air.


4. After the ice machine is in place, it should be parked for 12 hours after the first use.
5. Do not place objects or water containers on the ice machine.
6. Do not touch the live parts such as the power plug with wet hands.
7. In addition to professional repair personnel, no one should open the ice machine for repairs.
8. It is absolutely forbidden to modify the machine without authorization.
9. The power supply range is:
187V-242V/50Hz
10. The rated capacity of the wire should be >=6A, and the cross-sectional area of ​​the wire is 0.75mm2. For IM-80, the rated capacity of the wire should be >=10A, the cross-sectional area of ​​the wire is 1.Omm2, and the wire can be single or multiple. share. A fuse with a rated current of 5A (10A fuse for IM-80) is required.
11. Do not damage the power cord. If the power cord is processed, pulled, bundled, or placed on the power cord, once the outer sheath is damaged, the power cord may be damaged, resulting in electric shock or fire.
12 use temperature range: environment: 10 ° C -35 ° C, water temperature: 10 ° C - 30 ° C.
13. A separate three-hole socket must be used with a good grounding wire.

Third, the structure diagram


Rocker switch
2. Operation panel
3. Turn over the door
4. Power cord
5. Drain nut
6. Water valve
7. Outlet pipe
8. Adjustment nut
9. Ice spoon
10. Compressor
11. Inlet pipe
12. Drainage pipe

Fourth, use 1. Remove the outer packaging, and remove the attached file bag and inlet pipe, drain pipe, ice spoon, gasket and other accessories from the ice storage box.
2. Place the ice machine in a ventilated place, keep a space of not less than 150mm with the wall, keep away from the heat source, and ensure that the machine is placed smoothly.
3. Connect a 12 soft plastic corrugated drain pipe attached to the outlet pipe 7 on the back of the machine, and the other port is placed in the water tank (self-contained) or the sewer.
4. Connect one end of the supplied water inlet pipe to the faucet with 3/4" threaded joint of the drinking water supply pipe. The water pressure of the water supply pipe is 1.5-3kg/cm2, and the other end is connected with the water valve on the back of the ice machine. Threaded joints 6 are connected. Note that when connecting, seals (scheduled) are required at both ends of the inlet pipe.
5. Unscrew the tap to ensure the smooth flow of the inlet pipe.
6. Plug in the power plug and press the rocker switch on the operation panel. At this time, the ice machine starts working. The ice machine implements automatic continuous ice making from the water, ice making, ice removal and ice storage. The amount of ice inside reaches a certain level, the full ice light on the operation panel 2 will be on, and the ice machine will automatically stop; when the external water supply pipe (or pure water supply system) has water or water supply failure, the ice machine operation panel is short of water. The light will illuminate and the ice machine will automatically stop.

V. Daily maintenance 1. No matter whether the compressor is stopped for any reason (lack of water, excessive ice, power failure, etc.), it must not be started continuously. It should be restarted every 5 minutes to avoid damage to the compressor.
2. Regularly check the inlet and outlet connections to handle small amounts of residual water that may leak.
3. When the ice machine is not in use, please unscrew the plastic drain joint nut 5 on the back to drain the remaining water in the inner tank, and then wipe the storage tank with a clean cloth.
4. When the ambient temperature drops below 0 °C, there is the possibility of icing. Drainage must be carried out to release the water, otherwise the inlet pipe may be broken.
5. Unplug the ice machine when it is cleaned, inspected, and used for more than one week. When plugging or unplugging the power plug, apply the handheld plug and do not pull the power cord.
6. The drain pipe should be inspected one or two times a year to prevent blockage.

Sixth, technical parameters (measured under the condition of ring temperature 15 ° C, water temperature 10 ° C)

model

Ice making capacity
Kg/24h

Input power (W)

Refrigerant (g)
R 134a

Dimensions (mm)

IM-25 >=25

240

140

398 x 543 x 682
IM-25 >=25 240

140

380 x 543 x 672
IM-25A >=25 240

140

380 x 543 x 787
IM-50 >=50 380

230

548 x 611 x 833
IM-80 >=80 650

230

548 x 611 x 833

(The above parameters are subject to change without prior notice, subject to the parameters on the nameplate)

Seven, general faults and troubleshooting methods: (for users and maintenance personnel reference)

Fault phenomenon

cause

Method of exclusion

Ice machine does not work

1. The power supply voltage is lower than the specified lower limit of 187 V
2. The ambient temperature is lower than 10 °C
1. Stop immediately and restart after the voltage returns to normal.
2. Wait for the ambient temperature to rise above 10 °C to re-ice.
Water shortage light on the operation panel 1. Water supply system is short of water
2. The water valve is broken
3. Tap water pressure is too low
1. Check the water supply system to ensure that it is properly supplied and restarted.
2 Check the water valve.
3. If it is a tap water type ice machine,
The water pressure should not be lower than 1. Skg/cm 2 .

The compressor does not work

1. lack of water
2. Ice full
3. Compressor trip
(The case temperature is too high)
1. Check the water supply system (water valve and water supply pipe).
2. Remove some ice cubes.
3. Stop after 1 hour of shutdown.
Compressor works but does not make ice Refrigerant leakage
2. Refrigeration system blockage
3. Solenoid valve is always open
4. Condensing fan does not turn
5. Hall element without induction
1. Re-add refrigerant and check leaks.
2. Flushing system to replace the dry filter
3. Replace the solenoid valve.
4. Check if the condenser fan is running.
5. Check if the Hall element is intact.
There is no offset in the position.
Fault light on the operation panel 1. The ice is not completely taken off
2. The water box is not in place
1. Check if the solenoid valve can be opened. If not, replace the solenoid valve.
2. Check if the limit switch can sense the rotation of the eccentric wheel; check if the reverse motor and the eccentric wheel are slipping; turn the eccentric wheel by hand to check whether the motor gear is damaged.