The blast drying oven is a commonly used drying box equipment, which is mainly used for baking, drying, dissolving and disinfecting articles, and is widely used in industrial and mining enterprises, medical and health, biology, agriculture, chemical industry and the like. Today we mainly introduce the top ten use points of the blast drying oven, hoping to help users better apply the product. 1. After connecting the power supply, you can turn on the 2 sets of heating switches, and then set the temperature of the control instrument to the temperature you need. The indicator light is on and the blower switch can be turned on to make the blower work. 2. When the temperature rises to the desired temperature, the indicator light is off. At the beginning of the constant temperature, the temperature may continue to rise. This is the effect of residual heat, which will tend to stabilize in about half an hour. In the constant temperature process, the temperature control is automatically controlled by the thermostat in the box without manual management. 3. When the temperature is constant, a set of heating switches can be turned off, leaving only one set of electric heaters to work, so as to avoid excessive power and affect the sensitivity of the constant temperature. 4. The box should be placed indoors. 5. One of the knife switches of the iron shell should be installed in the power supply line for the purpose of this box and ground the casing. 6. Please check the electrical performance of the box before powering on, and pay attention to whether there is open circuit or leakage. 7. When everything is ready, put the sample, close the box door and unscrew the top exhaust valve. At this point, you can connect the power supply and start working. 8. Do not arbitrarily remove the side door, disturb or change the line. Only when the box fails, the side door can be removed and checked one by one. 9. This box is a non-explosion-proof drying box, so it has flammable volatiles, so do not put it in the dry box to avoid it. 10. Each drying oven is provided with two specimen shelves. The average load per shelf is 15 kg. Do not over-tighten and overload the test specimens to avoid affecting hot air convection. At the same time, the test piece should not be placed on the heat sink on the bottom of the studio to prevent overheating and damage the sample.
Medical Cold Patch
Patch For Diarrhea,Medicated Patches For Arthiritis,Plaster For Diarrhea,Pad For Diarrhea Shandong XiJieYiTong International Trade Co.,Ltd. , https://www.xjytmedical.com
Patch for diarrhea
[Name] Medical Cold Patch
[Package Dimension] 5cm 4pieces/box
The pain relief patch is composed of three layers, namely, backing lining, middle gel and protective film. It is free from pharmacological, immunological or metabolic ingredients.
[Scope of Application] For cold physiotherapy, closed soft tissue only.
[Indications]
The patches give a fast relief for diarrhea.
[How To Use a Patch]
Please follow the Schematic Diagram. One piece, one time.
The curing effect of each piece can last for 6-8 hours.
[Attention]
Do not apply the patch on the problematic skin, such as wounds, eczema, dermatitis,or in the eyes. People allergic to herbs and the pregnant are advised not to use the medication. If swelling or irritation occurs, please stop using and if any of these effects persist or worsen.notify your doctor or pharmacist promptly. Children using the patch must be supervised by adults.
[Storage Conditions]
Store below 30c in a dry place away from heat and direct sunlight.