Spreading refers to a fertilizing method that uses manpower or machinery to spread fertilizer evenly on the ground, and has the advantages of being simple, quick, and labor-saving. However, the disadvantages of spreading fertilizers are also many. On the one hand, fertilizer application is slow and results in great losses. The crop root system is the main organ for nutrient absorption. After the fertilizer is applied, it is rained or watered before it can exert its fertility. Most of the nutrients are easily lost and the utilization rate is extremely low. According to experimental research, the utilization rate of the urea strip or furrow can be achieved. 27%, while the utilization rate of the applicator is only 14%. On the other hand, if the fertilizer is spread on the leaves of the crop, it will also cause fertilizer damage, burning leaves and burning seedlings when light and high temperatures are applied. Fertilizer is added to the soil, the fertilizer is close to the roots of the crop, it is easy to be absorbed and utilized, and the utilization rate of fertilizer is high. Moreover, the contact surface between the fertilizer and the soil is small and the nutrient elements are fixed to a low degree, and the effective time is longer than the application. Therefore, when topsoil crops are topdressed, it is necessary to avoid spreading, to select furrows or plantings, and to fertilize soil to increase the utilization of fertilizers, save costs, and achieve high yields and high efficiency.
Ventilator block diagram Medical Positive Pressure Breathing Machine Positive Pressure Breathing Machine,Continuous Positive Pressure Ventilation,Intermittent Positive Pressure Ventilation,Intermittent Positive Pressure Breathing Machine Guangzhou Zhongzhinan Supply Chain Co.,Ltd. , https://www.gzzhongzhinan.com
One. Main mechanical ventilation modes
(1) Intermittent Positive Pressure Ventilation (IPPV): positive pressure in the inspiratory phase and zero pressure in the expiratory phase. 1. Working principle: The ventilator generates positive pressure in the inspiratory phase and presses the gas into the lungs. After the pressure rises to a certain level or the inhaled volume reaches a certain level, the ventilator stops supplying air, the exhalation valve opens, and the patient's thorax Passive collapse of the lungs and exhalation. 2. Clinical application: Various patients with respiratory failure mainly based on ventilation function, such as COPD.
(2) Intermittent positive and negative pressure ventilation (IPNPV): the inspiratory phase is positive pressure and the expiratory phase is negative pressure. 1. How it works: The ventilator works both in the inspiratory and exhaled phases. 2. Clinical application: Expiratory negative pressure can cause alveolar collapse and cause iatrogenic atelectasis.
(3) Continuous positive pressure airway ventilation (CPAP): Refers to the patient's spontaneous breathing and artificial positive airway pressure during the entire respiratory cycle. 1. Working principle: Inspiratory phase gives continuous positive pressure air flow, and exhalation phase also gives a certain resistance, so that the airway pressure of inhalation and exhalation phases are higher than atmospheric pressure. 2. Advantages: The continuous positive pressure airflow during inhalation is greater than the inspiratory airflow, which saves the patient's inhalation effort, increases FRC, and prevents the collapse of the airway and alveoli. Can be used for exercise before going offline. 3. Disadvantages: great interference to circulation, large pressure injury of lung tissue.
(4) Intermittent command ventilation and synchronized intermittent command ventilation (IMV / SIMV) IMV: There is no synchronization device, the ventilator air supply does not require the patient's spontaneous breathing trigger, and the time of each air supply in the breathing cycle is not constant. 2. SIMV: There is a synchronization device. The ventilator gives the patient a commanded breath according to the pre-designed breathing parameters every minute. The patient can breathe spontaneously without being affected by the ventilator. 3. Advantages: It exerts its ability to regulate breathing while offline; it has less influence on circulation and lungs than IPPV; it reduces the use of shock medicine to a certain extent. 4. Application: It is generally considered to be used when off-line. When R <5 times / min, it still maintains a good oxygenation state. You can consider off-line. Generally, PSV is added to avoid respiratory muscle fatigue.
(5) Mandatory ventilation per minute (MMV) When spontaneous breathing> preset minute ventilation, the ventilator does not command ventilation, but only provides a continuous positive pressure. 2. When spontaneous breathing is less than the preset minute ventilation volume, the ventilator performs command ventilation to increase the minute ventilation volume to reach the preset level.
(6) Pressure Support Ventilation (PSV) Definition: Under the prerequisite of spontaneous breathing, each inhalation receives a certain level of pressure support, increasing the patient's inhalation depth and inhalation volume. 2. How it works: The inspiratory pressure begins with the patient's inspiratory action, and ends when the inspiratory flow rate decreases to a certain level or the patient attempts to exhale hard. Compared with IPPV, the pressure it supports is constant, and it is adjusted by the feedback of the inspiratory flow rate. Compared with SIMV, it can get pressure support for each inhalation, but the level of support can be set according to different needs. 3. Application: SIMV + PSV: used for preparation before off-line, can reduce breathing work and oxygen consumption Indications: Exercise the ventilator; prepare before going offline; the ventilator is weak due to various reasons; severe flail chest causes abnormal breathing. 5. Note: Generally not used alone, it will produce insufficient or excessive ventilation.
(7) Volume Supported Ventilation (VSV): Each breath is triggered by the patient's spontaneous breathing. The patient can also breathe without any support and can reach the expected TV and MV levels. The ventilator will allow the patient to be truly autonomous Breathing also applies to preparations before going offline.
(8) Capacity control of pressure regulation
(IX) Biphasic or bilevel positive pressure ventilation How it works: P1 is equivalent to inspiratory pressure, P2 is equivalent to breathing pressure, T1 is equivalent to inspiratory time, and T2 is equivalent to exhalation time. 2. Clinical application: (1) When P1 = inspiratory pressure, T1 = inspiratory time, P2 = 0 or PEEP, T2 = expiratory time, which is equivalent to IPPV. (2) When P1 = PEEP, T1 = infinity, P2 = 0, T2 = O, which is equivalent to CPAP. (3) When P1 = inspiratory pressure, T1 = inspiratory time, P2-0 or PEEP, T2 = desired controlled inhalation cycle, equivalent to SIMV.