What problems should be paid attention to when installing and debugging the reactor module of the weighing module?

The weighing module is a very practical and convenient product. Therefore, it is extremely popular with everyone, so it is often used, so what are the precautions when installing and debugging?

Note that the reactor weighing module should be debugged:

1. Before commissioning, it is necessary to check whether the top nut of the support screw of each reactor weighing module has been loosened, and whether the sleeve is in a free state. Otherwise, a large error will occur, and even the weighing cannot be performed.

2. When debugging, check whether the factory setting value of each parameter meets the actual needs, especially the “power-on zero” parameter. Generally, it is set to “automatically clear” when it is shipped from the factory. Automatically clear at startup to prevent the material weight of the container from being cleared and lost when the machine is turned on again due to power failure.

3. The range setting does not refer to the rated total load of a set of reactor weighing modules, nor the weight of the container itself, but should be based on the weighing of the materials, and select the greater than or equal to the indexing and division values ​​given in the manual. Weight as a range.

4. The power supply voltage of the weighing display must meet the requirements. If the voltage is unstable and exceeds the allowable range, digital drift will occur. Use a regulated power supply.

5. Because the weighing system consisting of the weighing module of the reaction kettle is convenient for automatic weighing of the process and convenient for networking with the computer, it will be more and more widely used in chemical enterprises.

Note the installation of the reactor weighing module:

The reactor weighing module should pay attention to the horizontal adjustment, including the horizontal adjustment between the installation plane of a single module and a set of reactor weighing modules.

When welding, the sensor can't pass current. When welding the top plate, the ground wire should be connected to the scale body. When welding the bottom plate, the ground wire should be connected to the foundation to prevent damage to the sensor.

Reactor weighing module If there is a conveying pipe on the scale body, it should be replaced with a hose, or the connecting pipe should be as long as possible to prevent them from eating the actual load of the sensor and causing errors.

A weight calibration table is welded to the container for verification. There is generally no place to place the weight on the container, and it is necessary to weld a platform to place the weight. Usually welded under the container for easy weighting up and down.

The junction box must be protected from moisture and the excess holes should be plugged with a sealing plug. If the junction box is installed outdoors, a protective box must be added to prevent rain. In the event of a failure due to moisture in the junction box during use, it must be given sufficient attention.