Stainless steel transfer window cleaning and proper use

Stainless steel transfer window cleaning method

Stainless steel transfer window is a kind of clean auxiliary equipment, mainly due to clean and non-clean areas or non-clean and non-clean areas, the purpose is to reduce the number of door opening and reduce bacterial pollution. The stainless steel transfer window has the effect of sterilization and reducing bacterial pollution. However, if the inside is not cleaned after a period of use, the bacteria that grow inside will not only sterilize, but will further contaminate the transfer material in the transfer window.

Introduce the use and cleaning of stainless steel transfer windows.

1. Use the special cleaning cloth for the transfer window, disinfectant to clean the inner wall of the transfer window, the ceiling of each corner, the UV lamp tube, the transfer window door, etc., for the dirt accumulation thick, you can use the brush, disinfectant to clean the dirt, necessary Disinfect with disinfectant.

2 , in the use of rust steel transfer window during the use of UV light irradiation disinfection.

3 , to develop a good habit of regularly cleaning the stainless steel transfer window, disinfection transfer window inside and outside after use every week.

5. When the stainless steel transfer window is cleaned, after the professional inspector has checked and cleaned, the “cleaned” status indicator card will be attached to indicate that it can be put into normal use.

Correct use of stainless steel transfer windows

The stainless steel transfer window is an air purification device used in the clean room. It is suitable for small and medium cargo transfer between clean room or clean room and non-clean room, so as to reduce the number of door opening, so as to reduce the pollution of bacteria to the clean area.

The stainless steel transfer window has the correct method of use. Only through the correct method can it be used to ensure a longer service life and also achieve the true purification effect of the transfer object.

1. The two doors of the stainless steel transmission window should be kept in the closed state during use. There is a transmission window of the electric lighting system. Plug in the power plug first and connect the 220V/50Hz power supply.

2. When it is necessary to disinfect and sterilize the articles conveyed in the stainless steel transmission window, the power switch of the ultraviolet sterilization lamp can be turned on. At this time, the ultraviolet sterilization lamp lights up and is disinfected and sterilized according to the regulations.

3. For the electronic interlocking stainless steel transfer window, when opening the door of one side transfer window, the other side door is automatically locked, so when transferring the item, first open the door of the transfer window, and the required pass After the item is placed in the transfer window, the stainless steel transfer window door is closed. After the sterilization process, the door on the other side of the transfer window can be opened. The same person will immediately close the stainless steel door after removing the transferred items, so as not to affect the next time. The delivery of the item.

4. If the stainless steel transfer window is used to transfer the items, immediately turn off the power switch and unplug the power cord to ensure safe use.

Stainless steel transfer window use process

The stainless steel transfer window is a kind of clean auxiliary equipment, which is mainly used for clean and non-clean areas to reduce the number of door opening and reduce the pollution of pollutants. At present, the material of the transmission window in the market is rich, and the application is more A number of stainless steel transfer windows.

The stainless steel transfer window has a certain operational flow:

1. Wipe the item to be delivered with 0.5% peroxyacetic acid or 5% iodophor.

2. Open the outer door of the transfer window, quickly place the items to be delivered, disinfect the transfer window with 0.5% peracetic acid spray, and close the outer door of the transfer window.

3. Open the UV lamp in the transfer window and irradiate the object to be delivered for at least 15 minutes.

4. Inform the experimenter or staff in the barrier system, open the inner door of the transfer window, and remove the item.

5. Close the inner door of the transfer window.

Shanghai Sujing Industrial Co., Ltd.
  
If you have any needs, you can always pass with me, thank you very much for your support to Sujing, look forward to working with you.
  
have a pleasant workday!
  
Thankyou&Bestregard!
  
SUJING—JINGHUA

Fresh Peeled Garlic

Fresh Peeled Garlic,Storing Fresh Garlic,Storing Chopped Garlic,Preserving Peeled Garlic

shandong changrong international trade co.,ltd. , https://www.cragriculture.com